Translator
-
Articoli recenti
- Analysis of the report: “Observation of excess heat by activated metal and Deuterium gas”
- Analisi del documento: “Observation of excess heat by activated metal and deuterium gas”
- ENEA Rapporto 41 – Analisi e critica tecnica del contenuto
- A replica hypothesis for Rossi’s E-Cat: Method to simulate an apparent self-sustained system or COP>1
- Come è possibile spiegare il COP apparente>1 o “l’autosostentamento” dell’E-Cat
- How to overestimate water flux by wrongly positioning an instrument
- Come sovrastimare il flusso d’acqua posizionando uno strumento nel modo sbagliato
- TPR2 – Calorimetry of Hot-Cat performed by means of IR camera
- TPR2 – Calorimetria del Hot-Cat eseguita utilizzando una Termocamera IR
- Further measurements on the MD-6K-N pump used by Tadahiko Mizuno
Archivi
Categorie
Archivi tag: English
A replica hypothesis for Rossi’s E-Cat: Method to simulate an apparent self-sustained system or COP>1
Revision 1: 25/06/2016 Abstract This article describes a system that is able to provide a possible conventional explanation (not necessarily the only one) about the “self-sustained” phenomenon observed in the E-Cat steam-generator. During a few tests performed on the above-mentioned … Continua a leggere
How to overestimate water flux by wrongly positioning an instrument
Report written on: 19/04/2016 This Post was triggered by a discussion concerning the energy measurements published in this document of May 2013 (Provisional Patent Application US61/821,914) and by the statements of a user on the 22passi Blog (nickname: Hermano Tobia), who does not believe that … Continua a leggere
TPR2 – Calorimetry of Hot-Cat performed by means of IR camera
First issue: 08/02/2015 Introduction Some recent experimental measurements by the Martin Fleischmann Memorial Project (MFMP) highlighted a possible error in the Hot-Cat calorimetric measurement; the calorimetric measurement we are referring to is described in the document known as “TPR2” or … Continua a leggere
Pubblicato in Hot-Cat - Calorimetria, Hot-Cat - Calorimetria - Calorimetro a flusso
Contrassegnato English
19 commenti
Further measurements on the MD-6K-N pump used by Tadahiko Mizuno
First issue: 10/01/2015 Publication: 10/01/2015 Translation: 12/01/2015 After reading recently a comment (posted in the mail-archive vortex-l by Dave Roberson) regarding our recent calorimetry measurement of the magnetic drive pump Iwaki MD6, followed by a post that tried to explain … Continua a leggere
Calorimetry measurement on the MD-6K-N pump used by Tadahiko Mizuno
First issue: 24/12/2014 Pubblication: 05/01/2015 Translation: 07/01/2015 This article reports the verification activities and the calorimetry measurement performed on the pump used by Tadahiko Mizuno during his recent measurement of the alleged anomalous heat due to LENR, which was discussed … Continua a leggere
Analysis of Jed Rothwell’s Report about his calorimetry performed on Mizuno’s cell
First issue: 30/11/2014 Pubblication: 04/12/2014 Revision 1: 06/12/2014 Translation: 10/12/2014 Revision 2: 10/01/2015 Translation: 12/01/2015 Recently, on November 14, 2014 Jed Rothwell published a Report about a calorimetric measurement, performed in the period 16 to 24 October 2014, in the … Continua a leggere